Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
JACC Case Rep ; 4(17): 1119-1123, 2022 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-36090156

RESUMEN

Post-acute sequelae of severe acute respiratory syndrome coronavirus 2 (PASC) infection is particularly concerning to athletes who place a high premium on cardiovascular performance and competition. This initial case series shows the overlap between PASC and orthostatic intolerance in athletes, reveals the diagnostic challenges, and highlights the role of graded exercise training in this population. (Level of Difficulty: Advanced.).

2.
J Am Heart Assoc ; 10(24): e021893, 2021 12 21.
Artículo en Inglés | MEDLINE | ID: mdl-34873927

RESUMEN

Background Objective markers of cardiac function are limited in the outpatient setting and may be beneficial for monitoring patients with chronic cardiac conditions. We assess the accuracy of a scale, with the ability to capture ballistocardiography, electrocardiography, and impedance plethysmography signals from a patient's feet while standing on the scale, in measuring stroke volume and cardiac output compared with the gold-standard direct Fick method. Methods and Results Thirty-two patients with unexplained dyspnea undergoing level 3 invasive cardiopulmonary exercise test at a tertiary medical center were included in the final analysis. We obtained scale and direct Fick measurements of stroke volume and cardiac output before and immediately after invasive cardiopulmonary exercise test. Stroke volume and cardiac output from a cardiac scale and the direct Fick method correlated with r=0.81 and r=0.85, respectively (P<0.001 each). The mean absolute error of the scale estimated stroke volume was -1.58 mL, with a 95% limits of agreement of -21.97 to 18.81 mL. The mean error for the scale estimated cardiac output was -0.31 L/min, with a 95% limits of agreement of -2.62 to 2.00 L/min. The changes in stroke volume and cardiac output before and after exercise were 78.9% and 96.7% concordant, respectively, between the 2 measuring methods. Conclusions In a proof-of-concept study, this novel scale with cardiac monitoring abilities may allow for noninvasive, longitudinal measures of cardiac function. Using the widely accepted form factor of a bathroom scale, this method of monitoring can be easily integrated into a patient's lifestyle.


Asunto(s)
Gasto Cardíaco , Monitoreo Fisiológico , Volumen Sistólico , Estudios de Factibilidad , Humanos , Monitoreo Fisiológico/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...